OPTICAL FIBER
Quality Optical Fiber !
Small and Large core with a variety of jacketing.
HOMELAND SECURITY
FORCE PROTECTION Products !
Tactical Safety & security lighting products.
Fiber Optic - Optic Fibers |
||||||||||||
STA-FLEX LEF 710M LINEAR EMITTING FIBER |
||||||||||||
| Project: Type: Solid Optic Fiber Cable Catalog Number: LEF710M System Component: Optical Fiber |
|
|||||||||||
| DESCRIPTION: |
||||||||||||
|
Lumenyte LEF710M is the brightest linear optical
fiber in the industry today. It provides solutions
to numerous lighting applications for both issues
of luminance (perceived brightness of product when
directly viewed) and luminance (resultant
foot-candles or lux on a task). LEF710M's
flexibility makes it ideal for applications like
backlighting, neon replacement and signage.
Suitable for exterior, interior and water feature
use, it is manufactured in 6" (152mm) increments
and sold by the foot. Like all LEF products, it is
"driver dependant". |
||||||||||||
|
||||||||||||
| SPECIFICATIONS: | ||||||||||||
| Series Number | LEF710M | |||||||||||
| Core Diameter | .74” (18.8 mm) | |||||||||||
| Outer Diameter | 1.00” (25.5 mm) | |||||||||||
| Operating Temperature Range | Up to 194° F (90° C) | |||||||||||
| Weight of Optical Fiber (Average per Foot) | 6.78 oz. (190 g.) | |||||||||||
| Recommended Bend Radius | 12” Radius (304.8mm) | |||||||||||
| Beam Angle | 30° BEAM SPREAD (Nominal) | |||||||||||
![]() |
||||||||||||
| LEF710M: 12” Radius (304.8mm) 12” Radius (304.8mm) 12” Radius (304.8mm) | ||||||||||||
|
||||||||||||
| Recommended Distances for Effective LEF710M Brightness | ||||||||||||
| • The effective light-length-output of LEF710M
fiber optic is subjective and based upon several
variables such as: |
||||||||||||
|
||||||||||||
| • Shorter runs, up to 35’ (10.7m) from one light source or up to 45’ (13.7m) with a light source at each end, are recommended. | ||||||||||||
| Driver | ||||||||||||
| • The LEF Series is “driver dependent”. Therefore,
driver length(s) must be specified at time of
placing order. Driver lengths of up to 10’ (3m)
have minimum impact on photometric performance on a
straight run. The minimum bending radius of the
fiber is 12” (304.8mm) or greater. A second driver
is required when fiber is lit from both ends. Environment. |
||||||||||||
| Mounting | ||||||||||||
| Environment | ||||||||||||
| • Optical fiber core must be protected in wet or sunlit areas. Use end seals where applicable. | ||||||||||||
| • Protect core and cladding from dirt and abrasions. | ||||||||||||
| •Install fiber at temperatures of 10° C (50° F) or
higher. |
||||||||||||
| •Prior to installation, unbox optical fiber and lay
fiber straight for several hours. |
||||||||||||
| •Not for underwater use. | ||||||||||||